( O2 Gas detector ) The effect of oxygen-deficient and oxygen-enriched atmospheres


The effect of oxygen-deficient and oxygen-enriched atmospheres

The concentration of oxygen( percent )

Symptoms (atmospheric pressure)

100 percent

Deadly, 6 minutes(Absolutely airtight environment, such as hyperbaric oxygen chamber

50 percent

Deadly, can be cured after 45 minutes treatment. (Absolutely airtight environment, such as hyperbaric oxygen chamber)

>23.5 percent

Rich oxygen

20.96 percent

Normal

19.5 percent

Minimum

1519 percent

Reduce efficiency, and lead to problems of head, lung and circulation system

1012 percent

Shortness of breath, loss of judgment, purple lips

810 percent

governance loss, syncope, unconscious, pale, nausea and vomiting

68 percent

8 minutes, blood pressure, weak heartbeat,mouth breathing, quickly stopped breathing

46 percent

40 seconds, convulsions, respiratory arrest, death